Listing 1
public void correlateAlarm ( Alarm alarm )
{
//Related Alarms
//When a switch raises an equipment failure alarm ignore all
//communication failure alarms on the associated port.
if ((alarm.type == Alarm.Type.CommunicationFailure)
&& (alarm.managedObject.type ==
NetworkElement.Type.Port))
{
// search for Equip failure on Switch
AlarmList alarms = GetHistoryAlarmList();
for (Alarm a = alarms.firstElement();
alarms.hasMoreElements(); a = alarms.nextElement())
if ((a.type == Alarm.Type.EquipmentFailure)
&& (alarm.managedObject.type == NetworkEle-
ment.Type.Switch)
&& (a.managedObject.node == alarm.managedObject)) {
alarm.terminate(
"Terminated Communication Failure on Port
due to Equipment Failure on the Switch " +
alarm.managedObject.id);
return;
}
}
//Maintenance Activity Scheduled
//When maintenance activity has been scheduled on a net-
//work element ignore all alarms raised on this piece
//of hardware between the maintenance start and end time.
MaintenanceActivityList activities = GetMaintenanceActiv-
ityList(alarm.managedObject);
for (MaintenanceActivity maintenance =
activities.firstElement();
activities.hasMoreElements(); maintenance = activi-
ties.nextElement())
if ((alarm.time >= maintenance.startTime)
&& (alarm.time <= maintenance.endTime) {
alarm.terminate("Terminated due to a maintenance
activity on "
+ alarm.managedObject.id);
return;
}
// Critical Alarms on Sensitive Devices
// When more than 15 alarms are detected on a Network Element,
// notify the Network Operator by Pager.
// When more than 5 alarms are detected on a Switch,
// notify the Network Operator by Pager.
AlarmList alarms = GetHistoryAlarmList();
int count = 0;
int countOnSwitch = 0;
for (Alarm a = alarms.firstElement();
alarms.hasMoreElements(); a = alarms.nextElement()) {
if (alarm.managedObject == a.managedObject) {
count++;
if (alarm.managedObject.type ==
NetworkElement.Type.Switch)
countOnSwitch++;
}
}
if (count > 15)
network.pageOperator("More than 15 alarms on the NE " +
alarm.managedObject.id);
else if (countOnSwitch > 5)
network.pageOperator("More than 5 alarms on the Switch " +
alarm.managedObject.id);
} // public void correlateAlarm
Listing 2
//Related Alarms
//When a switch raises an equipment failure alarm ignore all
//communication failure alarms on the associated port.
rule Port_CommunicationFailure_due_to_Switch_EquipmentFailure
{
priority = maximum;
when
{
?alarm: Alarm(type == Alarm.Type.EquipmentFailure);
?switch: Switch() from ?alarm.managedObject;
?comm: Alarm(type == Alarm.Type.CommunicationFailure);
Port(node == ?switch) from ?comm.managedObject;
}
then
{
modify ?comm
{
terminate("Terminated Communication Failure on Port due
to Equipment Failure on a Switch");
}
}
};
//Maintenance Activity Scheduled
//When maintenance activity has been scheduled on a network
//element ignore all alarms raised on this piece of hardware //between
the maintenance start and end time.
rule Terminate_Alarms_During_Maintenance
{
priority = high;
when
{
?maintenance: MaintenanceActivity();
?alarm: Alarm(managedObject == ?maintenance.managedObject ; time >=
?maintenance.startTime ; time <= ?maintenance.endTime);
}
then
{
modify ?alarm
{
terminate("Terminated due to a maintenance window on " +
?maintenance.managedObject.id);
}
}
};
// Critical Alarms on Sensitive Devices
// When more than 15 alarms are detected on a Network Element,
// notify the Network Operator by Pager.
// When more than 5 alarms are detected on a Switch,
// notify the Network Operator by Pager.
rule Page_Operator_When_Critical_Alarm_On_Network_Element
{
when
{
?n: Network();
?networkElement: NetworkElement();
collect Alarm(managedObject == ?networkElement)
where (size() >15);
}
then
{
?n.pageOperator("More that 15 alarms on the NE " + ?net
workElement.id);
}
};
rule Page_Operator_When_Critical_Alarm_On_Switch
{
when
{
?n: Network();
?switch: Switch();
collect Alarm(managedObject == ?switch)
where (size() > 5);
}
then
{
?n.pageOperator("More that 5 alarms on the Switch" + ?switch.id);
}
};
No comments: